Silent drainage





Valsir
SILERE
- Versatile transition couplings: a wide range of adapters connects the SILERE® system to other drainage systems such as cast iron, PE, PP and PVC
- Applications: internal waste and rainwater drainage in residential buildings, industrial properties, hospitals and hotels where high acoustic comfort is required
- The SILERE VBF system additionally provides effective ventilation of the drainage stack and branch lines in tall buildings
Approvals















Technical data
| Material / construction | Single-layer, thick-walled blend of polypropylene and mineral fillers (density 1600 kg/m³, EN ISO 1183-2) |
| Diameters | Ø 58 mm - Ø 160 mm |
| Sound level | LSC,A = 6 dB(A) at 2 l/s flow (EN 14366); LIN = 9 dB(A) (DIN 4109) |
| Fire class | Euroluokka C-s3,d0 (EN 13501-1) |
| Operating temperature | Wastewater max. +95 °C (intermittent) / +80 °C (continuous); min. service temperature −20 °C |
| Chemical resistance | Wastewater pH 2–12; halogen-free; independent of stray currents |
| Pressure resistance | −500 mbar … +1.5 bar (20 °C; also suitable for central vacuum systems) |
| Application area | / standards |
| Application area | B (EN 1451-1); reference standards EN 1451-1 · WMTS-508:2013 · NBK 19 |
| Pipe lengths | 150 mm - 3 m |
BIM objects:SILERE ▸
Request a quote ▸ 




Valsir
TRIPLUS
Approvals

























Technical data
| Material / construction | Three-layer mineral-reinforced polypropylene (PP + MD); inner and outer layers PP, middle layer PP + mineral filler |
| Diameters | Ø 32 mm - Ø 250 mm |
| Fire class | D-s3,d0 (EN 13501-1) |
| Sound level | LSC,A = 12 dB(A) at 4 l/s flow · less than 10 dB(A) at 2 l/s (EN 14366; Fraunhofer Stuttgart, certificate P-BA 105/2024) |
| Operating temperature | Wastewater +95 °C (intermittent) / +80 °C (continuous); lower service limit −25 °C. |
| Chemical resistance | wastewater pH 2–12; halogen-free material. |
| Application area | EN 1451, application area B (installations inside buildings and wall-mounted outdoor installations) |
| Standards | EN 1451-1 · EN 13501-1 · EN 14366 Firestop collar (Collarwings), up to EI 240 (EN 1366-3), diameters 32–160 mm; rating depends on the pipe and construction specified in the installation instructions |

Valsir · Blackfire
Blackfire VBF ventilation branch fitting
D 110 stack connection · 6 inlets for horizontal runs
Product information
- Ventilation branch fitting for the Blackfire stack: D 110 connection and six inlets for horizontal pipe runs
- Three upper DN 100 (OD 110 mm) connections for sanitary fixtures (WC, washbasin, shower) and three D 75 inlets
- Standard achievable flow rate 13 l/s; higher flows subject to system design (Valsir technical support)
- Welding sockets from factory or on site · SBR seals
- Blackfire material: self-extinguishing mineral-filled PP, UV resistant, halogen free · B1 fire reaction (DIN 4102-1)
Technical details
| Stack connection | D 110 mm |
| D 110 inlets | max 3 |
| D 75 inlets | max 3 |
| Flow rate | 13 l/s (standard); higher per system design |
| Seals | SBR |
| Operating temperature | +80 °C continuous / +95 °C intermittent · waste pH 2–12 |

Valsir
Isolante - thermo-acoustic insulation for waste systems
Open-cell PU 12 mm + fire-resistant loaded rubber 2 mm · Rw 27 dB
Product information
- Thermo-acoustic insulation for Valsir waste systems: open-cell PU foam 12 mm + loaded fire-resistant rubber layer 2 mm (total 14 mm)
- Sound insulation Rw 27 dB (ISO 717-1) · acoustic class A2 (ISO 15665)
- Self-extinguishing: UL 94 HF1 · DL-s2,d0 (EN 13501-1)
- Eco-compatible: no bitumen, halogens or phosphates
- Sheets 1000 × 2000 mm · working temperature −70 … +110 °C (peak +140 °C)
Technical details
| Total thickness | 14 mm (PU 12 mm + rubber 2 mm) |
| PU density | 30 kg/m³ (UNI 6394 / ISO 1855) |
| Rubber surface weight | 4.5 kg/m² |
| Sound insulation | Rw 27 dB (ISO 717-1) · class A2 (ISO 15665) |
| Fire class | UL 94 HF1 · DL-s2,d0 (EN 13501-1) |
| Thermal conductivity | 0.035 W/mK (ISO 2581) |
| Working temperature | −70 … +110 °C · peak +140 °C |
| Format | sheets 1000 × 2000 mm |
Valsir
Parts and accessories

Restraint collars
Prevent pipes and fittings from slipping out of the socket under pressure or external stress; allow thermal movement. For Triplus and White Marine systems.
Request a quote ▸See also
Systems
Potable waterDrainageSilent drainageFire protectionDrains and trapsToilets and sanitaryFlush platesUnderfloor heatingComposite radiatorsElectric radiatorsAir convectorsVentilation HRVWater treatmentSolutions
ASENSI buildingEnergy solutionPrefabricationMarineMunicipal systemsBIM librariesOur principalsOrder from the Asensi shop
Prices and ordering for logged-in customers; the web shop is in Finnish. Project deliveries direct to site.