The full drainage range for every need and project

Why several drainage systems? Choose by application.

One manufacturer, several systems: each optimised for a different requirement.

SystemWhen you needNoise level (EN 14366)Advantage
SILEREMost demanding acoustic classes (hotels, care, high-rise)6 dB(A) @ 2 l/s
Fraunhofer P-BA 223/2006
Mineral-reinforced, extra sound-attenuated premium DB drainage: cast-iron acoustics at plastic weight and cost.
TRIPLUSSound-attenuated DB drainage for new-build and renovation12 dB(A) @ 4 l/s
P-BA 105/2024
Three-layer mineral-reinforced PP.
HDPEWeldable system, special and marine projectsButt- and electro-weldable PE-HD, seamless and durable; DN 32–160.
RAINPLUSSiphonic roof drainage, large roofs, 0° horizontal runsSiphonic vacuum system; weldable, compatible with the HDPE system.
PP3 FIREPLUSFire-resistant DB drainage, concealed installationunder 10 dB(A) @ 2 l/s · 15 dB(A) @ 4 l/sFire class B-s1,d0 (EN 13501-1); PP socket jointing, DN 50–160. Full range on the Fire protection page.
BLACKFIREFire-resistant DB drainage for exposed installation with good UV resistanceunder 10 dB(A) @ 2 l/s · 13 dB(A) @ 4 l/s
P-BA 258/2019e
Black colour for visible runs and plant rooms, good UV resistance.
PP3General building drainageunder 11 dB(A) @ 2 l/s · 18 dB(A) @ 4 l/s (EN 14366)Three-layer PP drainage system.
PPECOFORTEBuried gravity sewer (site and municipal)Three-layer PP-HM, Ø 110 mm - Ø 500 mm, ring stiffness up to SN16; UV-stabilised outer layer.

Decibel drainage = sound level max 10 dB(A) at 2 l/s (EN 14366).

SILERESILERE 2SILERE 3SILERE 4
Valsir

SILERE

  • Versatile transition couplings: a wide range of adapters connects the SILERE® system to other drainage systems such as cast iron, PE, PP and PVC
  • Applications: internal waste and rainwater drainage in residential buildings, industrial properties, hospitals and hotels where high acoustic comfort is required
  • The SILERE VBF system additionally provides effective ventilation of the drainage stack and branch lines in tall buildings
ApprovalsEMIETAITBLAPIRISESINTEFSUNDAHUSVIK
Technical data
Material / constructionSingle-layer, thick-walled blend of polypropylene and mineral fillers (density 1600 kg/m³, EN ISO 1183-2)
DiametersØ 58 mm - Ø 160 mm
Sound levelLSC,A = 6 dB(A) at 2 l/s flow (EN 14366); LIN = 9 dB(A) (DIN 4109)
Fire classEuroluokka C-s3,d0 (EN 13501-1)
Operating temperatureWastewater max. +95 °C (intermittent) / +80 °C (continuous); min. service temperature −20 °C
Chemical resistanceWastewater pH 2–12; halogen-free; independent of stray currents
Pressure resistance−500 mbar … +1.5 bar (20 °C; also suitable for central vacuum systems)
Application area/ standards
Application areaB (EN 1451-1); reference standards EN 1451-1 · WMTS-508:2013 · NBK 19
Pipe lengths150 mm - 3 m
BIM objects:SILERE
Request a quote
TRIPLUSTRIPLUS 2TRIPLUS 3TRIPLUS 4
Valsir

TRIPLUS

ApprovalsAENORCSIEMIGREENITBQBRISESINTEFSKZVIKWATERMARKDNVLLOYDSREGISTER
Technical data
Material / constructionThree-layer mineral-reinforced polypropylene (PP + MD); inner and outer layers PP, middle layer PP + mineral filler
DiametersØ 32 mm - Ø 250 mm
Fire classD-s3,d0 (EN 13501-1)
Sound levelLSC,A = 12 dB(A) at 4 l/s flow · less than 10 dB(A) at 2 l/s (EN 14366; Fraunhofer Stuttgart, certificate P-BA 105/2024)
Operating temperatureWastewater +95 °C (intermittent) / +80 °C (continuous); lower service limit −25 °C.
Chemical resistancewastewater pH 2–12; halogen-free material.
Application areaEN 1451, application area B (installations inside buildings and wall-mounted outdoor installations)
StandardsEN 1451-1 · EN 13501-1 · EN 14366 Firestop collar (Collarwings) EI 240 (EN 1366-3), diameters 32–160 mm
Request a quote 📄 Brochure (PDF)
HDPEHDPE 2HDPE 4
Valsir

HDPE

ApprovalsAENORBENORCSIEMIETAGREENIIPIISKIWAQBRISESINTEFSKZSUNDAHUSSWISSIPROCESSSWISSQUALITYVIKWATERMARKLLOYDSREGISTERRINA
Technical data
Material / constructionHigh-density polyethylene PE 80 (PE-HD); uniform single-layer wall, pipes and fittings Jointing method Butt welding (manual/machine) and electrofusion coupling; also push-fit socket with lip seal, flange and threaded joints
DiametersØ 32 mm - Ø 315 mm
Wall-thickness seriesSDR 26 (S 12.5) and SDR 33 (S 16)
Fire classEuroluokka E (EN 13501-1) · B2 (DIN 4102-1) · M4 (NF P 92-505)
Operating temperature−40 … +95 °C (intermittent); +80 °C continuous
Pressure rangeVacuum −800 mbar (SDR 26) / −450 mbar (SDR 33); overpressure +5 bar (SDR 26) / +4 bar (SDR 33), with socket joints +0.5 bar
Chemical resistanceWastewater pH 0–14; chemical resistance per ISO/TR 10358; halogen-free
Application area(EN 1519) B / D / BD · above-ground, buried and cast-in-concrete installation
StandardsEN 1519-1 (construction) · EN 13501-1 (fire classification) · ISO/TR 10358 (chemical resistance)
BIM objects:HDPE
Request a quote 📄 Brochure (PDF)
RAINPLUS 2RAINPLUS 3RAINPLUS 4RAINPLUS
Valsir

RAINPLUS

ApprovalsDITEMIITBRISE
Technical data
Material / constructionSiphonic full-bore system; roof-outlet body and flanges of stainless steel AISI 304, EPDM seals; pipework of single-layer PE-HD (PE 80, carbon-black stabilised, UV-resistant)
DiametersØ 32 mm - Ø 315 mm
Wall-thickness seriesSDR 26 and SDR 33
Flow rate (roof outlet)Rainplus 110-S up to 65 l/s (Ø 110 mm vertical connection); Rainplus 56-S up to 16 l/s (Ø 56 mm vertical/horizontal connection)
Fire class (reaction to fire)Class M4 (NF P 92-505); Class B2 (DIN 4102-1); Euroclass E (EN 13501-1)
Operating temperature+95 °C intermittent / +80 °C continuous; lowest service temperature -40 °C (welded joints min. -5 °C)
Pressure rangeVacuum at 20 °C -800 mbar (SDR 26) / -450 mbar (SDR 33); overpressure +5 bar (SDR 26) / +4 bar (SDR 33) without socket joints, +0.5 bar with socket or repair couplings
StandardsRoof outlets EN 1253-2 / EN 1253 and ASME A112.6.9; PE-HD pipes EN 1519-1
EPD declarationEPDITALY0407 (declaration 2023WASTEHDPE0407); ISO 14025 and EN 15804:2012+A2:2019; valid until 18 April 2028, cradle to grave
BIM objects:RAINPLUS
Request a quote 📄 Brochure (PDF) MagiCAD: RAINPLUS
Fire-resistant drainage systems

The same drainage lines in fire-resistant versions - the full fire range with firestop collars on its own page: Fire protection.

PP3 FIREPLUS 1PP3 FIREPLUS 2
Valsir

PP3 FIREPLUS

ApprovalsAENOR
Technical data
Material / constructionPolypropylene (PP), three-layer construction · flame retardant in every layer; mineral-reinforced middle layer
DiametersØ 40 mm - Ø 250 mm
Fire classB s1 d0 (EN 13501-1)
Sound insulationLsc,A = less than 10 dB(A) at 2 l/s · 15 dB(A) at 4 l/s (EN 14366, Fraunhofer Stuttgart, OD110)
Heat resistance+95 °C intermittent / +80 °C continuous; wastewater pH 2–12
Operating temperatureMinimum service temperature 0 °C; high impact resistance down to –10 °C
Application area(EN 1451) Area B · inside buildings and fixed to the wall outdoors; can also be cast directly into concrete Joint Push-fit socket with lip seal (SBR seal); slip coupling also available
StandardsEN 13501-1 · EN 1451-1 · EN 14366 FIRE RESISTANCE B-s1,d0 Tested to EN 13501; for hospitals, hotels and apartment buildings.
BIM objects:PP3 FIREPLUS
Request a quote 📄 Brochure (PDF)
BLACKFIRE 1BLACKFIRE 2
Valsir

BLACKFIRE

ApprovalsPZVIK
Technical data
Material / constructionBlack polypropylene, three-layer construction (co-extrusion); self-extinguishing additive in all layers; halogen-free
DiametersØ 32 mm - Ø 160 mm
Fire classB1 (DIN 4102-1) · self-extinguishing
Sound levelAcoustic comfort: below 10 dB(A) at 2 l/s and 13 dB(A) at 4 l/s (EN 14366, certificate P-BA 258/2019e)
Operating temperature−10 °C ... +95 °C (short-term) / +80 °C (continuous)
pH resistancewastewater pH 2–12 Pressure and application class Gravity drainage: over
Operating temperatureapplication area B (EN 1451)
Max working pressure+1.5 bar, vacuum −800 mbar (suitable for central vacuum systems)
StandardsEN 1451-1 (construction); EN 14366 · DIN 4109 (acoustics); DIN 4102-1 (fire)
Pipe lengths150 mm - 3 m
BIM objects:BLACKFIRE
Request a quote
PP3PP3 2PP3 3PP3 4
Valsir

PP3

ApprovalsCSIEMIITBITCGLAPILNEPZQBRISESKZVIKRINA
Technical data
Material / constructionPolypropylene (PP), three-layer pipes (outer layer grey PP, middle layer mineral-filled PP, inner layer white PP); single-layer fittings PP-H
DiametersØ 32 mm - Ø 160 mm
Fire classD-s3,d2 (EN 13501-1)
Sound insulationunder 11 dB(A) at 2 l/s · 18 dB(A) at 4 l/s (EN 14366)
Operating temperature−10 °C … +95 °C intermittent / +80 °C continuous wastewater Wastewater
pH resistancepH 2–12
Application areaclass (EN 1451) B (inside buildings and fixed to the wall outdoors)
StandardsEN 1451-1 (product standard) · EN 13501-1 · EN 14366 Jointing method Push-fit socket with lip seal (pre-fitted SBR seal); slip coupling and double-socket fittings also available
BIM objects:PP3
Request a quote 📄 Brochure (PDF) 📄 Brochure (PDF)
Municipal and buried systems

Buried sewers, cable-duct inspection chambers and stormwater management - the same supply chain as building services: Municipal systems.

Valsir

Parts and accessories

AirVal air admittance valve
Vents the waste system without a roof penetration - prevents syphonage and odours (EN 12380, CE + UKCA).
Request a quote
Transition fittings
A wide range of transition fittings for connecting SILERE and TRIPLUS to other waste systems (cast iron, PE, PP, PVC).
Request a quote
Ventilation branch fittings
Ventilation branch fittings for the stack without a separate vent pipe - for TRIPLUS, SILERE and Blackfire systems.
Read more
Isolante insulation
Thermo-acoustic insulation for waste systems: PU 12 mm + fire-resistant rubber 2 mm · Rw 27 dB.
Read more
Special fittings
Hundreds of special fittings for every system and project - branches, bends, access fittings, traps.
Restraint collars
Prevent pipes and fittings from slipping out of the socket under pressure or external stress; allow thermal movement. For Triplus and White Marine systems.
Request a quote

Project deliveries

Project-specific orders, delivery direct to site.

Request a quote