Heating and cooling




Valsir
RADIANT-SYSTEM
Technical data
| Diameters | Ø 14 mm - Ø 110 mm |
| Fire class | (pipe) C-s2,d0 (EN 13501-1) |
| Impact sound reduction (system) | ΔLw > 28 dB, V-Acoustic with 100 kg/m² screed (UNI EN 12354-2) |
| Operating temperature | +95 °C / +100 °C |
| max. pressure | 10 bar |
| Application class | Class 4 (4a) underfloor heating, EN ISO 21003-1 · certified for all four classes up to 10 bar |
| Standards | Pipe: EN ISO 21003; sizing and installation: UNI EN 1264 |




Valsir
THERMOLINE
Technical data
| Material | PE-X (Thermoline) and PE-RT with EVOH oxygen-diffusion barrier |
| Diameters | 16×2 / 17×2 mm, coils 240–600 m |
| Service life | At least 50 years per product standards |
System components
Panels, pipes, manifolds, controls and dehumidification - the complete underfloor heating system from one supplier.

Panel types
Six panel systems from residential to industrial: V-ESSE (apartments, 50–60 mm), V-ERRE0 (low 22 mm for renovations), V-ERRE and V-ERRE GRAFITE (EPS 32–82 mm), V-ELLE + V-RAIL (flat panel, industrial and open spaces), V-EFFE (XPS: larger pipe size in industrial projects, smaller in normal houses).






Pipes - PE-X, PE-RT and composite
Thermoline PE-X pipes, PE-RT EVOH pipes (16×2 / 17×2, coils 240–600 m) and Mixal composite pipes with oxygen-diffusion barrier.

Manifolds - steel and PA-M
Manifolds delivered pre-assembled with flow meters, setting memory lock, shut-off valves plus air-vent and drain valves. PA-M models are modular - also suitable for cooling; steel models also for large projects.

Manifold cabinets
Metal cabinets for surface and flush mounting.
Widths 400–1200 mm (e.g. 400×810×150 · 600×800×130 · 1200×810×150)



Pump and mixing units
After the hydraulic separator the manifold is connected with a compact connection kit and modules that deliver water at the right temperature and flow: PV1 mixing modules and the V-MIX03 mixing kit.

Controls
Wi-Clima Evo combines a winter and summer chronothermostat, a humidity controller and, when needed, HRV control in one device. Also available: a concealed touch-screen thermostat plus conventional chronothermostats and hygrostats.



V-Dryair - dehumidification for cooling
Isothermal dehumidifiers to pair with floor cooling - they integrate with the HRV system.
Models: 260 V EVO · 260 H · 520 H EVO



Industrial projects
Heating large halls without temperature stratification: lower energy consumption, smaller heat generators and a low flow temperature suited to heat pumps and waste-heat recovery.
Industrial sizes: body sizes 1″ · 1″¼ · 1″½
Heating calculator
Indicative material estimate for a quotation request. Calculation runs in your browser.
Heating method:
Radiators
Type:
Floor structure
Material estimate
| Item | Amount |
|---|---|
| UFH pipe (estimate 4.2–4.3 m/m²) | |
| Installation panel | |
| Minimum build height | |
| Heating circuits (estimate) | |
| Manifold outlets | |
| Thermostats (rooms + wet rooms) | |
| Radiators (estimate: rooms + wet rooms) | |
| Low-temperature aluminium radiators (Aleternum) also work with heat pumps; model sizes are dimensioned with the radiator calculator. | |
| Total power demand (at given W/m²) | |
| Model suggestion (measured outputs) | |
| Cooling readiness: control with dew-point guard | |
The estimate is indicative and meant for requesting a quotation. Sizing is refined in the design phase.
Go to the shop ▸ Request a quote with this estimate ▸ PDF is currently unavailable. Size the models with the radiator calculator ▸ Exact sizing with the calculator ▸Based on official Valsir system data.
See also
Systems
Potable waterDrainageSilent drainageFire protectionDrains and trapsToilets and sanitaryFlush platesUnderfloor heatingComposite radiatorsElectric radiatorsAir convectorsVentilation HRVWater treatmentSolutions
ASENSI buildingEnergy solutionPrefabricationMarineMunicipal systemsBIM librariesOur principalsOrder from the Asensi shop
Prices and ordering for logged-in customers; the web shop is in Finnish. Project deliveries direct to site.
Open the shop ▸